Part Number Hot Search : 
MMBT2 CAT5138 RUN21D22 PC357N2T 90100 1N627 A56A1 OSB5SA
Product Description
Full Text Search
 

To Download PENT1080 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  ___________________________________________________ ___________________________________________________ ________________________ 1 of 2 sl power electronics corp ? 6050 king drive ventura, ca 93003 ? phone 805.486.4565 ? fax 858.712.2040 ? email: info@slpower.com ? www.slpower.com specifications all specifications are typical at nominal input, fu ll load at 25 c unless otherwise stated . ac input 100-240vac, -10%,+6%, 47-63 hz single phase. mtbf >100,000 hours (calculated) input current 115vac: 1.4a, 230vac: 0.7a. hold - up time 16.7 ms min. @ 115vac, 20ms min. @ 230vac inrush current inrush limiting provided. overvoltage protection built-in, latch off input fuses internal primary current fuse is provided. overload protection foldback mode earth leakage current class ii: <250 a, class i: <750 a. short circuit protection hiccup mode efficiency 80% typical. topology flyback switching type output power 80w continuous. safety standards en/iec/ul 60950-1, csa22.2, no. 950, 2 nd edition ripple and noise 1% pk-pk max., 20mhz bw, differential mode. isolation input-output: 3000vac output voltage see chart. operating temperature 0 to 40 c, no derating line & load voltage regulation excluding cord: +/- 1%. storage temperature -20 to +85 c. minimum load not required. relative hu midity 5% to 95%, non-condensing transient response 500 s max., 50% load step, typical. altitude 0 to 10,000 ft. case dimensions: desktop style: 8.34? x 2.24? x 1.48?. case material: black 94v-0 rated polycarbonate output connections: dual rj-45 jacks built-in. power on led: provided on all models PENT1080 80 watt power over ethernet injectors compliant/non-compliant, 10/100 and gigabit injecto rs 2 year warranty ? 10/100 and 10/100/1000 (mbps) data rate models ? self-contained injector ? 100-240vac universal input ? desktop style/non-vented case ? ieee802.3af detection and disconnection compliant, and non-compliant models ? power on led ? overload shutdown and short circuit protection ? regulated output with low ripple
___________________________________________________ ___________________________________________________ ________________________ 2 of 2 sl power electronics corp ? 6050 king drive ventura, ca 93003 ? phone 805.486.4565 ? fax 858.712.2040 ? email: info@slpower.com ? www.slpower.com    custom label artwork options (contact factory for cost/availability) :    custom agency approvals available    surge protection (input & output)    mounting bracket    other modifications "personalized" poe input receptacle options iec320 - c8 iec320 - c14 iec320 - c14 "shaver" grounded ungrounded (n) (f) (q) 01 = standard. 02 and higher indicates a modified model. model configuration: model number key 56 00 pent 01 1 080 a f input connector: "f" = iec320 c14 grounded, "q" = iec320 c14 ungrou nded, "n" = iec320 c8. (see chart below) output connector: "00" = dual rj45 jacks output voltage: "56" = 56vdc model configuration: a = non-compliant, gigabit, b = compliant gigabit, c = non-compliant 10/100baset, d = compliant 10/10 0baset product family : "p" = poe, "e" = external, "nt" = new technology output power: "080" = 80 watts # of outputs model number output volts output current (max) max watts ripple (vp-p max) PENT1080 a 5600 f 01 56 v 1.42 a 80.0 w 560mv emc specifications all specifications are typical at nominal input, fu ll load at 25 c unless otherwise stated . data sheet ? 2011 sl power electronics corp. the i nformation and specifications contained herein are believed to be correct at the time of publication. rev. 8-24-2011 however, sl power accepts no responsibility for con sequences arising from reproduction errors or inacc uracies. specifications are subject to change with out notice. emissions en55022 class b, fcc part 15, class b. static discharge immunity en61000-4-2, cd level 2, ad level 3, criteria b radiated rf immunity en61000-4-3, level 2, criteria a eft/burst immunity en61000-4-4, level 2, criteria a line surge immunity en61000-4-5, level 3, criteria b harmonic en61000-3-2, class a PENT1080 80 watt power over ethernet injectors compliant/non-compliant, 10/100 and gigabit injecto rs 2 year warranty j2 j1 (data in) j1 j2 data (gigabit only) pins 4/5: data (gigabit only) + pwr) data pins 1/2 (data + pwr) data pins 3/6 (data + rtn) data (gigabit only) pins 7/8: data (gigabit only) + rtn) note: = transformer PENT1080 pinout connections: (power & data out) output/data connections


▲Up To Search▲   

 
Price & Availability of PENT1080

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X